YJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin Interface

Brand Name : Evita

Model Number : OOM202

Place of Origin : Germany

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 500

Delivery Time : 5-8 days

Packaging Details : Canned

Measurement range : 0-100%

Output signal in air : 13-16mv

Circuit interface : 3-pin (molex)

Accuracy and repeatability : <1% volume

Linear error : <3% relative error

Response time : <12 seconds

Contact Now

Product Description:

OOM202 Medical Oxygen Sensor (Oxygen Battery Oxygen Probe)

Features:

Oxygen sensor (O2 sensor, oxygen battery, oxygen probe, oxygen electrode) OOM202

Measurement range: 0-100%

Output signal in air: 13-16mv

Circuit interface: 3-pin (molex)

Accuracy and repeatability: <1% volume oxygen, after calibration in 100% oxygen

Linear error: <3% relative error

Response time: <12 seconds, relative to 90% of the relative value

Zero drift: <200μV placed in 100% ammonia for 5 minutes

The influence of temperature: -0.03% relative humidity, 25℃

The influence of pressure: It is proportional to the partial pressure of oxygen

Mechanical shock influence: <1% relative error, after falling from a height of 1 meter

Operating temperature: 0℃ to 50℃

Temperature compensation: Built-in thermistor compensation

Temperature influence: 25℃ to 40℃, with a relative error of 3%

Compensation (steady-state) : 8% relative error between 0℃ and 50℃

Working humidity: 0-99% RH (can condense in the air for several hours)

Storage temperature: -20℃ to 50℃

Recommended storage temperature: 5℃ to 15℃

Recommended load: ≥10Ω

Preheating time: <30 minutes, after replacing the sensor

Rated sensor life: ≥ 100,0000% volumetric oxygen hours

Weight: Approximately 28G

Main features: Compatible with various imported brands of anesthesia and respiratory equipment, it has a long-standing oxygen sensing technology and is widely used in the medical, aviation, diving and other industries.

Applicable brands: Siemens /Servo series /Vent.300/V710 300, EnviteC OOM202/103/106, City Technologies City Technology MOX-01, Maxtec MAX-12, Sensidyne Xingsida /SV-12A, MSA 472032/470644, Taema YR049700/Cesar2, Bird products: Bird brand Avea Vent, Puritan Bennett NP840 Vent.4-074925-00, SensorTech/ST-12/ST-04, Pacifiech/PT-12A, Teledye, Ventrex, VTI, EME, Hamilton, Hudson RCI, Infrasonics, Integral Process

Specifications:

Recommended load ≥10Ω
Preheating time <30 minutes, after replacing the sensor
Rated sensor life ≥ 100,0000% volumetric oxygen hours
Weight Approximately 28G

YJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin InterfaceYJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin InterfaceYJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin InterfaceYJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin Interface


Product Tags:

3-Pin Interface Oxygen Sensor

      

Medical Oxygen Sensor

      

3% Linear Error Oxygen Sensor

      
Wholesale YJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin Interface from china suppliers

YJJ OOM202 Medical Oxygen Sensor Oxygen Battery Oxygen Probe 3% Linear Error 3-Pin Interface Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)